Sign In | Join Free | My himfr.com
Home > Electromagnetic Flow Meter >

Insertion Type Electromagnetic Flow Meter

    Buy cheap Insertion Type Electromagnetic Flow Meter from wholesalers
     
    Buy cheap Insertion Type Electromagnetic Flow Meter from wholesalers
    • Buy cheap Insertion Type Electromagnetic Flow Meter from wholesalers

    Insertion Type Electromagnetic Flow Meter

    Ask Lasest Price
    Brand Name : JSHQ
    Model Number : HQ-LDE
    Certification : CE, MC, CQC, SIL, ISO
    • Product Details
    • Company Profile

    Insertion Type Electromagnetic Flow Meter


    1. Product Brief Introduction:

    HQ-LDE intelligent electromagnetic flowmeter consists of two parts: sensors and converters. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging and other fields for flow measurement. Plug-in electromagnetic flowmeter is suitable for measuring all corrosive and conductive liquids.

    2. Product Features:

    All digital processing, strong anti-interference ability, reliable measurement, high accuracy, and a flow measurement range of up to 150:1.
    Ultra low EMI switching power supply, suitable for a wide range of power supply voltage changes, with good EMI resistance performance.
    Adopting a 16 bit embedded microprocessor, it has fast computing speed, high accuracy, programmable low-frequency rectangular wave excitation, improved stability of flow measurement, and low power consumption.
    Using SMD devices and surface mount technology, the circuit has high reliability.
    There are no movable parts or flow blocking components inside the pipeline, and there is almost no additional pressure loss during measurement.
    On site, the range can be modified online according to the actual needs of the user.
    The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc.
    High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand.
    It has digital communication signal outputs such as RS485, RS232, Hart, and Modbus. (Optional)
    It has self checking and self judging functions.
    Hourly total volume recording function, recording the total flow volume in hours, suitable for time-sharing measurement system (Optional)
    There are three integrators inside that can display the forward cumulative amount, reverse cumulative amount, and difference cumulative amount respectively. There is also a non power outage timer inside that can record 16 power outage times. (Optional)
    Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact operation converter (Optional).

    3. Product Performance:


    Nominal diameter: pipeline type DN10~DN1200; Insertion type DN100~DN500

    Accuracy level: pipeline type 0.5 grade, 1.0 grade; Insert-type full flow rate >1m/S, ±2.5 grade

    Temperature of the measured medium: Ordinary rubber lining: -20 ℃~+60 ℃

    High temperature rubber lining: -20 ℃~+90 ℃

    PTFE lining: -30 ℃~+100 ℃

    High temperature PTFE lining: -20 ℃~+180 ℃

    Power supply: AC220V, DC24V, 3.6V Battery

    Current output: load resistance 0~10mA: 0~1.5KΩ; 4~20mA: 0~750KΩ

    Connection type: Flange connection is used between the flow meter and the piping, the flange connection dimensions should comply with the provisions of GB1198


    4. Technical Specifications:

    Nominal diameter(mm)Pipeline type: DN4DN3000
    (Special specifications can be customized)Insertion type: DN100DN3000
    Flow direction:Positive, negative, net flow
    Range ratio:150:1
    Repetitive error:± 0.1% of the measured value
    Accuracy grade:Pipeline type: 0.5 grade, 1.0 grade
    Temperature of the tested medium:Ordinary rubber lining: 20~+60
    High temperature rubber lining: -20~+90
    PTFE lining: -30~+100
    High temperature PTFE lining: -20~+180
    Rated working pressure:DN6DN80: ≤1.6MPa
    (High pressure customizable)DN100DN250: ≤1.0MPa

    DN300DN1200: ≤0.6MPa
    Flow velocity range:0.1-15m/s
    Conductivity range:The conductivity of the measured fluid ≥5μs/cm
    Current output:Load resistance010mA: 01.5kΩ
    420mA: 0750 kΩ
    Digital frequency output:The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA.
    Power supply:AC220V,DC24V or 3.6V battery
    Require the length of the straight pipeSection to be ≥ 5DN upstream and ≥ 2DN downstream
    Connection method:The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988
    Explosion proof grade:mdIIBT4
    Protection level:IP65, specially customized up to IP68
    Environmental temperature:-25~+60℃
    Relative temperature:5%~95%
    Total power consumption: less than 20W20W


    5. Selection


    ① Selection code




    ModelDescription
    HQLDE —Rate of flow-□-□
    HQLDR —Heat quantity-□-□
    Path diameter












    10-2200mm
    TypeSElectromagnetic flowmeter (ordinary integrated type)
    BStainless steel electromagnetic flowmeter
    CInsertion type electromagnetic flowmeter
    DClamp type electromagnetic flowmeter
    EFire specific electromagnetic flowmeter
    FSmall caliber electromagnetic flowmeter
    GSanitary clamp electromagnetic flowmeter
    HBattery powered electromagnetic flowmeter
    LSplit type electromagnetic flowmeter
    JHigh pressure electromagnetic flowmeter
    KWireless remote electromagnetic flowmeter
    ISolar powered electromagnetic flowmeter
    Installation methodFFlange installation
    LThreaded installation
    KClamp installation
    Electrode materialMStainless steel
    TTi (Titanium)
    DTa (Tantalum)
    HHastelloy alloy
    PPt (Platinum)
    NNi (Nickel)
    ATungsten carbide (wear-resistant)
    Output method0No output
    14-20mA/1-5KHz
    24-20mA
    324V 4G Wireless remote transmission
    4Battery powered 4G wireless remote transmission
    Lining materialXRubber
    FPTFE
    PF46 (High temperature)
    JPFA (Wear resistant)
    T
    Ceramics
    On site display0No on-site display
    1On site display
    Communication method0No communication
    1RS485
    2RS232
    3Mobdus
    4Hart
    Grounding0No grounding ring
    1Have grounding ring
    2Have grounding electrode
    Upper limit rate of flow(n)Upper limit flow rate (range)
    m3/h
    Work pressureA0.6MPa
    B1.0 MPa
    C1.6 MPa
    D2,5 MPa
    Measurement accuracy10.2
    20.5
    31
    4
    1.5
    5
    2
    6
    2.5
    Medium temperatureL0-80
    H0-150
    Power supply methodDC24VDC
    AC220VAC
    DBattery-powered
    TSolar-powered


    Selection of caliber and flow rate


    Nominal diameter (mm)Measurable flow range (m³/h)Effective measurement of flow range (m³/h)Nominal diameter (mm)Measurable flow range (m³/h)Effective measurement of flow range (m³/h)
    40.01350.45220.01350.45222508.8313211952.98751766
    60.03051.01730.03051.017330012.717305276.3022543
    80.05431.80860.05431.808635017.314154103.863461
    100.01423.39120.08482.82640022.615425135.654521
    150.03187.63020.19086.358545028.626867171.685722
    200.056613.56480.339211.30450035.338478211.957065
    250.088321.1950.529817.662560050.8712208305.210173
    320.144734.72580.868229.938270069.2416616415.413847
    400.226154.25921.356545.21680090.4421703542.618086
    500.353384.782.119570.65900114.4627468686.722890
    650.5970143.283.5819119.391000141.333912847.828260
    800.9044217.035.4259180.861200203.548833122140694
    1001.413 339.128.478282.6140027766467166255389
    1252.2079529.8713.2468441.561600361.886814217172345
    1503.179376319.0755635.851800457.9109874274791562
    2005.652135633.9121130.4



    Quality Insertion Type Electromagnetic Flow Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hongqi Automatic Control (Jiangsu) Co., Ltd.
    *Subject:
    *Message: